HYAPF active power filter detects the load current in real-time through the external current transformer (CT), calculates the harmonic of the load current through the internal DSP, and sends it to the internal IGBT through the PWM signal, then generate a compensating current with the same amplitude but opposite phase angles to the detected harmonics to achieve the filtering function.
The HYSVG static var generator detects the load current in real-time through the external current transformer (CT), calculates the reactive power of the load current through the internal DSP, and sends it to the internal IGBT through the PWM signal according to the set value , then generate the required reactive compensation current to achieve the dynamic reactive compensation function.
● Harmonic compensation: APF can filter 2 ~ 50 times random harmonics at the same time
● Reactive power compensation: Capacitive & Inductive (-1 ~ 1) stepless compensation
● Fast response
● Design life is more than 100,000 hours (more than ten years)
● Capacitive & inductive load -1 ~ 1 compensation.
● Three-phase imbalance compensation.
● Working switching frequency is 10K, extremely fast response dynamic compensation.
HY | □ | - | □ | - | □ | / | □ | □ |
| | | | | | | | | | | | |||
1 | 2 | 3 | 4 | 5 | 6 |
No. | Name | Meaning | |
1 | Enterprise code | HY | |
2 | Product type | APF: active power filter SVG: static var generator | |
3 | Voltage level | 400V | |
4 | Capacity | 300A(200kvar) | |
5 | Wiring Type | 4L: 3P4W3L: 3P3W | |
6 | Mounting type | No mark: drawer typex A: cabinet typex B: Wall-mounted type (Three options) |
Normal working and installation conditions
Ambient temperature | -10°C~+40°C |
Relative humidity | 5%~95%, no condensation |
Altitude | ≤1500m, 1500~3000m (derating 1% per 100m) according to GB / T3859.2 |
Environmental conditions | no harmful gas and steam, no conductive or explosive dust, no severe mechanical vibration |
Outdoor installation | At least 15cm space should be reserved for the upper and lower air outlets of the module, and at [east 60cm space should be reserved for the front and rear of the cabinet for easy maintenance. |
System parameters | |
Rated input line voltage | 380V (-20% ~ +20%) |
Rated frequency | 50Hz (45Hz ~ 55Hz) |
Power grid structure | 3P3W/3P4W (400V) |
Current transformer | 100/5 ~ 5,000/5 |
Circuit topology | three-level |
Overall efficiency | ≥97% |
Standard | JB/T 11067-2011, DL/T 1216-2013 |
Performance
Response time | < 10ms |
Target power factor | 1 |
Intelligent air cooling | excellent ventilation |
Noise Level | < 65dB |
Communication monitoring capability