It adheres on the tenet "Honest, industrious, enterprising, innovative" to develop new items frequently. It regards buyers, success as its very own success. Let us produce prosperous future hand in hand for Universal Run Capacitor, Three Phase Power Capacitor, Active Power Filter, And we can help looking for any products of the customers' needs. Make sure provide the best Service, the Best Quality, The fast Delivery.
China Wholesale Auto Power Factor Controller Manufacturers - JKW series reactive power automatic compensation controller – LASTONE Detail:
Overview
JKW series reactive power automatic compensation controller is suitable for the automatic adjustment of capacitor compensation device of low voltage power distribution system (hereinafter referred to as the controller), so that the power factor can reach the user’s predetermined state, improve the utilization efficiency of power transformers, reduce line losses and improve voltage quality of power supply , thereby improving economic and social benefits.
Standard: JB/T 9663-2013
Features
● Calculate switching capacitor capacity with reactive power, high compensation accuracy
● Power factor measurement has high accuracy and wide display range.
● Initial phase preset (software adjusts the same terminal or current signal polarity)
● Two control modes: power factor and reactive power, HMI is easy to operate
● Various control parameters are fully digital adjustable and intuitive to use
● With two working modes: automatic operation and manual operation
● With over-voltage and under-voltage protection
● With data storage protection when power off
● The input impedance of the current signal is ≤ 0.01Ω.
Model and Meaning
JKW |
□ |
- |
□ |
/ |
□ |
| |
| |
|
| |
|
| |
1 |
2 |
|
3 |
|
4 |
No. |
Name |
Meaning |
|
1 |
Reactive power compensation controller |
JKG |
|
2 |
Enterprise code |
5C: equipped contactor |
D5: equipped composite switch |
3 |
Output Control step |
optional step: 4、6、8、 |
10、12 |
4 |
Rated voltage |
AC 220V or 380V |
|
Technical Parameters
Normal working and installation conditions |
Ambient temperature |
-25°C ~ +55°C |
Relative humidity |
Relative humidity % 50% at 40°C ; ≤90% at 20°C |
Altitude |
≤2000m |
Environmental conditions |
no harmful gas and steam, no conductive or explosive dustz no severe mechanical vibration |
Power condition |
|
Rated voltage |
220V±20%; THDv≤5%; |
Rated working current |
0~5A |
Rated frequency |
50Hz |
Performance |
|
Control step |
4, 6, 8, 1 0, 12 |
Measure reactive power |
0-9999 kvar |
Sensitivity |
60mA |
Over-voltage protection |
230-260V or 380-500V |
Output contact capacity |
JKW5C static AC 220V 7A 50Hz |
Output contact capacity |
JKWD5 Dynamic DC 12V 12mA |
Display power factor |
Lag: 0.001~lead: 0.001 |
Protection grade |
shell IP40 |
Switching delay |
1~250s |
Putting in threshold |
Lag: 0.70~lead: 0.70 |
Cutting off threshold |
Lag: 0.70~lead: 0.70 |
Dimension and structure |
|
|
Dimension WxHxD(mm) |
Hole dimension WxH(mm) |
|
JKW5C |
three phase compensation(equipped with AC contactor) |
122x112x95 |
113×113 |
JKW5C-6S |
three phase compensation(equipped with AC contactor) |
122x112x95 |
86×86 |
JKWD5 |
three phase compensation(quipped with composite switch) |
86x86x95 |
113×113 |
JKG2B |
three phase compensation(equipped with AC contactor) |
170x110x100 |
162×102 |
Product detail pictures:
Related Product Guide:
Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for China Wholesale Auto Power Factor Controller Manufacturers - JKW series reactive power automatic compensation controller – LASTONE , The product will supply to all over the world, such as: Paraguay, Greenland, Albania, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.