Project background
The central square of Ganjiang Greenland is located on the first line of the CBD of Rulehu New Town, the core of the national Ganjiang New District. It is a seven-in-one urban business complex integrating two super-high-rise landmarks, headquarters office, conference center, star-rated hotel, characteristic business, and talent apartment. The project is adjacent to Ganjiang New District Enterprise Headquarters Base, Binjiang Business District, Exhibition Business District, Ganjiang New District New Management Committee, and characteristic cultural and tourism towns, etc. It has Metro Line 1 (planning) and three-dimensional traffic along Jinshui Avenue along the Yangtze River Expressway. Changbei International Airport is about 7 kilometers away and 11 kilometers away from downtown Nanchang.
Applications
This project adopts harmonic control and reactive power compensation series products, including APF active filter modules, power capacitors, composite switches, reactors, controllers, etc. It is mainly used for harmonic control and reactive power compensation. It can effectively improve power factor and reduce losses while filtering harmonics, ensuring stable and reliable operation of power equipment.
Active filter product advantages
> Harmonic compensation: APF can filter out 2~50 harmonics at the same time
> Reactive power compensation: capacitive sensitivity (-1~ 1) stepless compensation
> Extremely fast response, instant management
> Design life is more than 100,000 hours (more than ten years)
The HYAPF active filter detects the load current in real time through the external current transformer CT, and extracts the harmonic components of the load current through the internal DSP calculation, and then sends it to the internal IGBT through the PWM signal to control the inverter to generate a harmonic component of the load. Currents with equal waves and opposite directions are injected into the power grid to compensate for harmonic currents to achieve filtering.
BSMJ series self-healing low-voltage parallel power capacitors are suitable for power frequency AC power systems with rated voltages of 1000V and below, to improve power factor and power quality.
CKSG series three-phase series filter reactors are often affected by harmonic current, closing inrush current and operating overvoltage when compensating capacitive reactive power, resulting in capacitor damage and power factor reduction. Install a three-phase filter reactor to suppress and absorb harmonics, protect capacitors, avoid the influence of harmonic voltages and currents and impulse voltages and currents, improve power quality, improve system power factor, and prolong capacitor service life.