JKW series reactive power automatic compensation controller

Short Description:

1. It is suitable for the automatic adjustment of capacitor compensationdevice of low voltage power distribution system

2. Two working modes:automatic operation and manual operation

3. With data storage protection when power off

4. Calculate switching capacitor capacity with reactive power,high compensation accuracy


Product Detail

Product Tags

Overview

JKW series reactive power automatic compensation controller is suitable for the automatic adjustment of capacitor compensation device of low voltage power distribution system (hereinafter referred to as the controller), so that the power factor can reach the user's predetermined state, improve the utilization efficiency of power transformers, reduce line losses and improve voltage quality of power supply , thereby improving economic and social benefits.

Standard: JB/T 9663-2013

Features

● Calculate switching capacitor capacity with reactive power, high compensation accuracy

● Power factor measurement has high accuracy and wide display range.

● Initial phase preset (software adjusts the same terminal or current signal polarity)

● Two control modes: power factor and reactive power, HMI is easy to operate

● Various control parameters are fully digital adjustable and intuitive to use

● With two working modes: automatic operation and manual operation

● With over-voltage and under-voltage protection

● With data storage protection when power off

● The input impedance of the current signal is ≤ 0.01Ω.

Model and Meaning

JKW - /
| | | |
1 2 3 4
No. Name Meaning  
1 Reactive power compensation controller JKG  
2 Enterprise code 5C: equipped contactor D5: equipped composite switch
3 Output Control step optional step: 4、6、8、 10、12
4 Rated voltage AC 220V or 380V  

Technical Parameters

Normal working and installation conditions
Ambient temperature -25°C ~ +55°C
Relative humidity Relative humidity % 50% at 40°C ; ≤90% at 20°C
Altitude ≤2000m
Environmental conditions no harmful gas and steam, no conductive or explosive dustz no severe mechanical vibration
Power condition  
Rated voltage 220V±20%; THDv≤5%;
Rated working current 0~5A
Rated frequency 50Hz
Performance  
Control step 4, 6, 8, 1 0, 12
Measure reactive power 0-9999 kvar
Sensitivity 60mA
Over-voltage protection 230-260V or 380-500V
Output contact capacity JKW5C static AC 220V 7A 50Hz
Output contact capacity JKWD5 Dynamic DC 12V 12mA
Display power factor Lag: 0.001~lead: 0.001
Protection grade shell IP40
Switching delay 1~250s
Putting in threshold Lag: 0.70~lead: 0.70
Cutting off threshold Lag: 0.70~lead: 0.70
Dimension and structure     Dimension WxHxD(mm) Hole dimension WxH(mm)
1 JKW5C three phase compensation(equipped with AC contactor) 122x112x95 113x113
JKW5C-6S three phase compensation(equipped with AC contactor) 122x112x95 86x86
JKWD5 three phase compensation(quipped with composite switch) 86x86x95 113x113
JKG2B three phase compensation(equipped with AC contactor) 170x110x100 162x102